Who's Online
There currently are 5996 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Very helpfull information and I highly recommend this source for needed information about your products.
;
More than pleased with my prurchase, very good product for the price.
;
This is a good quality scan of the service manual which includes an assembly diagram, block diagram, schematic, and parts list. Exactly what is needed to repair my KR-V55R receiver.
;
Excellent concise manual. All needed information was included. Typeface and diagrams were clear. Very fair price considering what others are charging. Many thanks
;
Response is a little slow- I had to wait 12 hours to receive download link but it says that it may take up to 24hrs.
Manual is old and was not produced in PDF- scanned copy is exellent.
Overall- value for money- I recommend
6. PRECAUTIONS FOR REPAIR : QW-1619 / 1622 / 1644 6-1. AC (ALL CLEAR) AND REMOVING OF MODULE
1.Perform AC (ALL CLEAR) when inserting a new battery, or else the memories and/ or counters may give erratic displays. Touch the AC contact and the positive (+) side of the battery or main plate with the metalic tweezers. The contact should be made for about two seconds. For 2 seconds after the AC operation, do not make any button operations on these modules. 2.On removing of the module from the case, please insert the precision screw driver between the module and the case pointed by arrows.
Metallic tweezers
6-2. ACCURACY CHECKING
Check the accuracy of the module with the quartz timer after switching the module to "ACCURACY CHECKING MODE". The operations are shown below: A) SWITCHING TO "ACCURACY CHECKING MODE" Keep pushing the D button and continuously push the A , C buttons at the same time at the normal time keeping mode. Then all the segments are displayed and the LCD drive signals are changed to the static drive signal of "32 Hz" so that you can check the accuracy with the quartz timer. B) CANCELLATION OF THE "ACCURACY CHECKING MODE" Push any button except D . Then the display is returned to its original state. NOTE: The "ACCURACY CHECKING MODE" will automatically return to the regular mode in 1 ~ 2 hour(s) without any operation.
QW-1619 / 1644 QW-1622