Who's Online
There currently are 217 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
Finally, i found one website, where i can download this service manual , and fix my hifi. The service manual is very good, and easy to download and to print.
 ;
Complete and very useful. Could have benefited from a little higher resolution on the schematic and layout diagrams for improved legibility.
 ;
Great Service Manual, Very Complete, as advertised, Perfect, Thanks!
 ;
Good quality service manual.It has helped me to fix my FV1800,particularly for replacing the dial cord.The scheme is on A3 format and very readable.Thank.Olivier.
 ;
This manual is complete and very readable.It was a great help for my two ICF5800L.The first one had the dial cord broken,and without the service manual it is impossible to replace it.Thank.Olivier.
6. PRECAUTIONS FOR REPAIR: MODULE QW-1559 / 1564 / 1565 6-1. AC (ALL CLEAR) AND REMOVING OF MODULE
1.Perform AC (ALL CLEAR) when inserting a new battery, or else the memories and/ or counters may give erratic displays. Touch the AC contact and the positive (+) side of the battery or main plate with the metalic tweezers. The contact should be made for about two seconds. For 2 seconds after the AC operation, do not make any button operations on these modules. 2.On removing of the module from the case, please insert the precision screw driver between the module and the case pointed by arrows.
Metallic tweezers
6-2. ACCURACY CHECKING
Check the accuracy of the module with the quartz timer after switching the module to "ACCURACY CHECKING MODE". The operations are shown below: A) SWITCHING TO "ACCURACY CHECKING MODE" Keep pushing the D button and continuously push the A , C buttons at the same time at the normal time keeping mode. Then all the segments are displayed and the LCD drive signals are changed to the static drive signal of "32 Hz" so that you can check the accuracy with the quartz timer. B) CANCELLATION OF THE "ACCURACY CHECKING MODE" Push any button except D . Then the display is returned to its original state. NOTE: The "ACCURACY CHECKING MODE" will automatically return to the regular mode in 1 ~ 2 hour(s) without any operation.
QW-1559 QW-1564 QW-1565
- 14 -
|
|
 |
> |
|