Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Who's Online
There currently are 475 guests and 
1 member online.
Categories
Information
Featured Product
Home >> CASIO >> PRG50T-7V Owner's Manual
 
 0 item(s) in your cart 

CASIO PRG50T-7V
Owner's Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of CASIO PRG50T-7V Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file after You purchase it.

Owner's Manual ( sometimes referred to as User's Guide or User's Manual ) contains information on how to use Your device. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 AG-H500 TEAC Owner's Manual by Werner Keil;
I was so pleased to get the owner`s manuel within one hour! Thanks again. Regards Werner
 CT-WM62R PIONEER Owner's Manual by Lucinda Phoenix;
Finding the owners manual for my Pioneer CRWM62R is greatly appreciated. I had searched several other web sites with no success. Although my manual was not listed on your site for immediate download, I recevied an email within a few hours that my ower's manual was posted for me. I had no difficulty downloading the manual for my 20 year old multi-cassette player. Owner Manuals provides a service that is valuable, easy-to-use, accurate , efficient, and priced fairly. I thank you.
 KT-2030L KENWOOD Owner's Manual by Alistair Hill;
Excellent manual - just what I needed. Although currently available only in German, their are lots of pictures which makes it all very clear.
 PE1642 PHILIPS Owner's Manual by Robert Schmid;
PHILIPS PE1642 Owner's Manual Hi, you have complet fullfilled my expectance. Price is OK. Robert Schmid
 WAK 4555 BAUKNECHT Owner's Manual by Rikke Jensen;
Came in the mail within a few hours. Gave clear instruktion on maintaines. Is of great use to have this manual in house

Text excerpt from page 8 (click to view)
USER’S GUIDE 2471
Precautions about bidirectional calibration • You can use any two opposing directions for bidirectional calibration. You must, however, make sure that they are 180 degrees opposite each other. Remember that if you perform the procedure incorrectly, you will get wrong bearing sensor readings. • Do not move the watch during the one or two seconds (from the point you press B up to the point that OK appears in the upper display area) that the calibration of each direction is in progress. • You should perform bidirectional calibration in an environment that is the same as that where you plan to be taking direction readings. If you plan to take direction readings in an open field, for example, calibrate in an open field.

To calibrate the temperature sensor

l l ll l l

1. Press C to enter the Barometer/ Thermometer Mode. 2. Hold down A until either OFF or a temperature value (if set) starts to flash, which indicates the setting screen. 3. Press E (+) or B (–) to change the displayed temperature by 0.1°C (or 0.2°F). • Pressing B and E at the same time returns to the factory calibration (OFF). 4. Press A to return to the Barometer/ Thermometer Mode screen.

To perform bidirectional calibration
1. Press B to enter the Digital Compass Mode. 2. Hold down A for about one second until the upper display area changes to show ---1---, which indicates the setting screen. • At this time, the magnetic north pointer flashes at the 12 o’clock position to indicate that the watch is ready to calibrate the first direction. 3. Place the watch on a level surface facing any direction you want, and press B to calibrate the first direction. • When the calibration procedure is complete, the message OK appears in the upper display area. This soon changes to ---2--- and the magnetic north pointer flashes at the 6 o’clock position to indicate that the watch is ready for the second direction. 4. Rotate the watch 180 degrees. 5. Press B again to calibrate the second direction. • The message OK appears and the watch automatically returns to the Digital Compass Mode screen.

Calibrating the Barometric Pressure Sensor
The pressure sensor of this watch is calibrated at the factory before shipment and further adjustment is normally not required. If you notice serious errors in the barometric pressure readings produced by the watch, you can calibrate the sensor to correct the errors. Important! Incorrectly calibrating the barometric pressure sensor can result in incorrect readings. Before performing the calibration procedure, compare the readings produced by the watch with those of another reliable and accurate barometer.

To calibrate the pressure sensor
l ll l l l l l

l

l

1. While in the Digital Compass Mode, hold down A for about one second until the upper display area changes to show ---1---, which indicates the setting screen. 2. Press D to start the northerly calibration procedure. • At this time, the indicator (direction N) appears in the upper display area. 3. Place the watch on a level surface, and position it so that its 12 o’clock position points north (as measured with another compass). 4. Press B to start the calibration operation. • The message OK appears and the watch automatically returns to the Digital Compass Mode screen.

l l

To perform northerly calibration

To change the Altitude Units
1. Press E to enter the Altimeter Mode. 2. Hold down A until the display clears. After four or five seconds, either OFF or the current reference altitude (if set) starts to flash, which indicates the setting screen. 3. Press D three times to move the flashing to the altitude unit setting. 4. Use E to select the unit you want (m or ft). 5. Press A to return to the Altimeter Mode screen. • Changing the altitude units automatically turns the altitude alarm off. • Changing the altitude units automatically restarts the altitude graph. • Performing the above procedure causes altitude values stored in memory also to be converted to the unit you select.

Changing the Barometric Pressure and Temperature Units
Changing the barometric pressure units automatically restarts the barometric pressure graph.

To change the Barometric Pressure and Temperature Units
1. Press C to enter the Barometer/ Thermometer Mode. 2. Hold down A until either OFF or a temperature value (if set) starts to flash, which indicates the setting screen. 3. Press D to move the flashing in the sequence shown below.

l l ll l l
l l ll l
l

Temperature Sensor Calibration

Pressure Sensor Calibration

°C / °F

hPa[mb]/inHg

4. Press D to move the flashing to the unit setting you want to change (°C/°F or hPa[mb]/inHg). 5. Use E to select the unit you want. 6. Press A to return to the Barometer/Thermometer Mode screen.

Calibrating the Temperature Sensor
The temperature sensor of this watch is calibrated at the factory before shipment and further adjustment is normally not required. If you notice serious errors in the temperature readings produced by the watch, you can calibrate the sensor to correct the errors. Important! Incorrectly calibrating the temperature sensor can result in incorrect readings. Carefully read the following before doing anything. • Compare the readings produced by the watch with those of another reliable and accurate thermometer. • If adjustment is required, remove the watch from your wrist and wait for 20 or 30 minutes to give the temperature of the watch time to stabilize.

lll

lll l l lll

ll l

l l ll l
l l ll l l l
lll

1. Press C to enter the Barometer/ Thermometer Mode. 2. Hold down A until either OFF or a temperature value (if set) starts to flash, which indicates the setting screen. 3. Press D to move the flashing to the pressure sensor calibration setting. • At this time, OFF or the barometric pressure value should be flashing on the display. 4. Press E (+) or B (–) to change the displayed barometric pressure by 1 hPa/mb (0.05 inHg). • Pressing B and E at the same time returns to the factory calibration (OFF). 5. Press A to return to the Barometer/ Thermometer Mode screen.

l

l l l

8

You might also want to buy

$4.99

SX-K700 TECHNICS
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

CJ-V51 PIONEER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

SX-PR602 TECHNICS
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG7330 PANASONIC
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

HC-P4752W SAMSUNG
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

SX-KN2000 TECHNICS
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG-7500 PANASONIC
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

VSX-95 PIONEER
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…
>
Parse Time: 0.149 - Number of Queries: 131 - Query Time: 0.037